TQC Wet Film Thickness

Category:

Description

Wet Film Thickness Gauge Stainless Steel

TQC Wet Film Thickness Gauge WG is a hexagonal or octagonal precision measuring comb, that it made by a heavy stainless steel. The high-grade stainless steel will not be affected by acid also base elements. Models available for several different applications.

Wet Film Thickness Gauges are designed to measure the thickness of coatings immediately after they have been applied to a substrate. The gauge has a series of notches cut into its sides like the teeth on a comb. The wet film thickness of coatings including paints, resins, lacquers, varnishes and gels an so on can be measured.

Hexagonal/Octagonal precision measuring comb made of heavy stainless steel. The high-grade stainless steel will not be affected by acid and base elements either.

Available in both Microns and Mils scale.

4 models available for several different applications:

SP4000 – WG I

WFT

Wet Film Thicknes

20-370 μm in 24 steps (6×4) for decorative paints and primers.

  • side 1: 20, 30 40,50
  • side 2: 60, 70, 80, 90
  • side 3: 100, 110, 120, 130
  • side 4: 150, 170, 190, 210
  • side 5: 230, 250, 270, 290
  • side 6: 310, 330, 350, 370

 

SP4010 – WG II

WFT Stainless Steel

WFT-WG4100

25-2000 μm in 36 steps (6×6) With edge grinding check (2mm) for protective coatings and high solids.

  • side 1: 25, 50, 75, 100, 125, 150
  • side 2: 175, 200, 225, 250, 275, 300
  • side 3: 350, 400, 450, 500, 550, 600
  • side 4: 650, 700, 750, 800, 850, 900
  • side 5: 950, 1000, 1100, 1200, 1300, 1400
  • side 6: 1500, 1600, 1700, 1800, 1900, 2000

SP4020 – WG III

WFT

Wet Film Thickness

50-10000 μm in 71 steps (8×9) Scale division: 0-900:50μm, 900-5500:100μm, 5500-9000:500μm for extremely thick films such as floor coatings, fillers, fire proofing, plaster, adhesives etc.

  • side 1: 50, 100, 150, 200, 250, 300, 350, 400, 450
  • side 2: 500, 550, 600, 650, 700, 750, 800, 850, 900
  • side 3: 1000, 1100, 1200, 1300, 1400, 1500, 1600, 1700, 1800,
  • side 4: 1900, 2000, 2100, 2200, 2300, 2400, 2500, 2600, 2700
  • side 5: 2800, 2900, 3000, 3100, 3200, 3300, 3400, 3500, 3600
  • side 6: 3700, 3800, 3900, 4000, 4100, 4200, 4300, 4400, 4500
  • side 7: 4600, 4700, 4800, 4900, 5000, 5100, 5200, 5300, 5400
  • side 8: 5500, 6000, 6500, 7000, 7500, 8000, 8500, 9000, 10000

 

SP4050 – WG II

Wet FIlm Thciness

WFT Stainless Steel

1-80 mils in 36 steps (6×6) With edge grinding check (2mm) for protective coatings and high solids.

  • side 1: 1, 2, 3, 4, 5, 6
  • side 2: 7, 8, 9, 10, 12, 14
  • side 3: 16, 18, 20, 22, 24, 26
  • side 4: 28, 30, 32, 34, 36, 38
  • side 5: 40, 42, 44, 46, 48, 50
  • side 6: 55, 60, 65, 70, 75, 80

Use

  • Place the gauge at a 90° angle to the coated substrate
  • Make sure the gauge is in firm contact with the substrate.
  • Remove the gauge in a straight line up.
  • Assess the teeth of the gauge. The wet film thickness lies between the largest tooth that is wet and the smallest tooth that is not wet.

Brand